Schedule 3 QUANTITY OF HAZARD TYPE 4 PYROTECHNIC ARTICLES IN SALES AREASI1
Northern Ireland
The maximum quantity of Hazard Type 4 pyrotechnic articles which may be kept for any period of time in a sales area at a site in relation to which a person is registered for the storage of explosives shall be the quantity specified in column 2 of the Table below corresponding to the floor area of the sales area shown in column 1 of the Table.
| 1 | 2 |
|---|---|
| Floor area of sales area | Quantity of explosives |
| (square metres) | (kilograms) |
| not exceeding 20 | 12.5 |
| not exceeding 40 | 15 |
| not exceeding 60 | 20 |
| not exceeding 80 | 25 |
| not exceeding 100 | 30 |
| not exceeding 150 | 35 |
| not exceeding 200 | 40 |
| not exceeding 250 | 45 |
| not exceeding 300 | 50 |
| not exceeding 350 | 55 |
| not exceeding 400 | 60 |
| not exceeding 450 | 65 |
| not exceeding 500 | 70 |
| exceeding 500 | 75 |