Paragraph 3 F1
Filling
Samples which can be filled—
Fill the article with a 4 % (v/v) acetic acid solution to a level no more than1 mm from the overflow point; the distance is measured from the upper rimof the sample. Samples with a flat or slightly sloping rim should be filled so that the distance between the surface of the liquid and the overflow point is no more than 6 mm measured along the sloping rim.
Samples which cannot be filled—
The surface of the sample which is not intended to come into contact with foodstuffs is first covered with a suitable protective layer able to resist the action of the 4 % (v/v) acetic acid solution. The sample is then immersed in a recipient containing a known volume of acetic acid solution in such a way that the surface intended to come into contact with foodstuffs is completely covered by the test liquid.