All reagents must be of analytical quality, unless otherwise specified.

Where reference is made to water, it shall always mean distilled water or water of equivalent quality.

(a)

4 % (v/v) acetic acid, in aqueous solution.

Add 40 ml of glacial acetic acid to water and make up to 1 000 ml.

(b)

Stock solutions.

Prepare stock solutions containing 1 000 mg/litre of lead and at least 500 mg/litre of cadmium respectively in a 4 % acetic acid solution, as referred to in paragraph 3(a).