OpenLegislation

Regulation 30 Dimensions of dipstick guide tubesI1

Northern Ireland Not yet in force

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

(1)

In the case of compartments used for petroleum spirit the dipstick guide tube shall—

(a)

be, throughout its depth of immersion, of not less than 50 mm internal diameter or equivalent cross-sectional area; and

(b)

have venting uniformly throughout its length of at least 0.01 square metre area per metre of length, excluding any gauze covering or retaining clips.

(2)

In the case of compartments used for liquid fuel other than petroleum spirit a dipstick guide tube shorter than the length of the dipstick may be used, but it shall be of such diameter and length that the dipstick is guided sufficiently near to the vertical plane so that any inaccuracy in the indication of quantity cannot exceed the prescribed limits of error.

Annotations

Commencement

I1

Reg. 30 in operation at 7.5.1984, see reg. 1(1)(a)