The Measuring Instruments (Automatic Catchweighers) (Use for Trade) Regulations (Northern Ireland) 2007
S.R. 2007/383 · Made 31 August 2007 · Extends to Northern Ireland
WEIGHTS AND MEASURES
Made 31st August 2007
Coming into operation 15th October 2007
The Department of Enterprise, Trade and Investmentf1 makes the following Regulations in exercise of the powers conferred by Article 13(1) of the Weights and Measures (Northern Ireland) Order 1981f2 and now vested in itf3.
Annotations to the whole text
Footnotes
- f1
-
Formerly the Department of Economic Development; see S.I. 1999/283 (N.I. 1), Art. 3(5)
- f2
-
S.I. 1981/231 (N.I. 10) as amended by 2000 c. 5 (N.I.)
- f3
-
By S.I. 1982/846 (N.I. 11) Art. 4
Contents
- 1Citation and commencement
- 2Interpretation
- 2ARegulation 2A
- 3Application
- 4Requirements for use for trade
- 5Manner of use
- 6Regulation 6
- 7Regulation 7
- 8Regulation 8
- 9Manner of erection and installation
- Signature
- Explanatory note
1Citation and commencementI1
These Regulations may be cited as the Measuring Instruments (Automatic Catchweighers) (Use for Trade) Regulations (Northern Ireland) 2007 and shall come into operation on 15th October 2007.
2InterpretationI1
In these Regulations—
“the 2006 Regulations” means the Measuring Instruments (Automatic Catchweighers) Regulations 2006f1;
“accuracy class” means the classification of an automatic catchweigher in accordance with paragraph 16 of Schedule 1 to the 2006 Regulations;
“automatic catchweigher” means an automatic weighing instrument that determines the mass of pre-assembled discrete loads (for example pre-packages) or single loads of loose material, but does not include an automatic checkweigher or an automatic weight grading instrument;
“automatic checkweigher” means an automatic catchweigher which sub-divides articles of different mass into two or more sub-groups according to the value of the difference between their mass and the nominal set point;
“automatic weight grading instrument” means an instrument which sub-divides articles of different mass into several sub-groups each characterised by a given mass range;
“essential requirements” means the requirements set out in Schedule 1 to the 2006 Regulations;
“instrument” has the same meaning as automatic catchweigher;
“place on the market” means making available for the first time in a member State an instrument intended for an end user, whether for reward or free of charge; and
“put into use” means the first use of an instrument intended for the end user for the purposes for which it was intended.
2AF1
In these Regulations a reference to member State includes Norway, Iceland or Liechtenstein.
3ApplicationI1
Subject to paragraphs (2) and (3), these Regulations apply to an automatic catchweigher which is—
for use for trade; and
first placed on the market or put into use on or after 15th October 2007.
These Regulations do not apply to an automatic catchweigher which comprises—
an automatic catchweight weighing machine for the purposes of the Weighing Equipment (Non-automatic Weighing Machines) Regulations (Northern Ireland) 2006f1; or
an automatic catchweighing instrument for the purposes of the Weighing Equipment (Automatic Catchweighing Instruments) Regulations (Northern Ireland) 2006f2,
in respect of which a certificate of approval has been granted before 15th October 2007 and is in force; and
which is first passed as fit for use for trade and stamped under either of those Regulations.
These Regulations do not apply to an automatic catchweigher to which the 2006 Regulations do not apply by virtue of regulation 3(3) to (4) thereof.
4Requirements for use for tradeI1
A person shall not use for trade an automatic catchweigher unless—
it is compliant with the essential requirements other than the provisions relating to maximum permissible errors referred to in paragraph 17 of Schedule 1 to the 2006 Regulations;
the requirements of regulations 5 to 8 are complied with;
it has been erected and installed in accordance with the requirements of regulation 9;
in the case of an automatic catchweigher of accuracy class Y(I), Y(II), Y(a), or Y(b) in automatic operation, it is within the maximum permissible error for that instrument as set out in Table 1 in Schedule 5 to the 2006 Regulations; and
in the case of an automatic catchweigher of accuracy class Y(I), Y(II), Y(a) or Y(b) in non-automatic operation, it is within the maximum permissible error for that instrument as set out in Table 2 in Schedule 5 to the 2006 Regulations.
5Manner of useI1
An automatic catchweigher marked with a measurement range may be used for trade for determining the weight of any item by ascertaining the difference between the weight of that item and a separate item, where both items fall within the measurement range.
6I1
Where an automatic catchweigher is marked with a measurement range a person shall not use that instrument for trade for determining a weight outside that range in relation—
to, or to articles made from, gold, silver or other precious metals, including gold or silver thread or fringe;
to precious stones or pearls; or
to drugs or other pharmaceutical products.
7I1
A person shall not use for trade an automatic catchweigher other than an instrument of accuracy class Y(I) or Y(II) in any transaction—
in, or in articles made from, gold, silver or other precious metals, including gold or silver thread or fringe; or
in precious stones or pearls.
8I1
Where an automatic catchweigher is marked with a temperature range, it shall not be used for trade in temperatures outside that range.
Where an automatic catchweigher bears a mark which signifies the manner and purpose of use, it shall not be used for trade in a manner or for a purpose which does not accord with that marking.
An automatic catchweigher of accuracy class Y(b) shall only be used for weighing ballast or waste.
An automatic catchweigher shall not be used for trade in circumstances—
in which it may be prevented from operating consistently or accurately; or
which are likely prematurely to degrade its metrological characteristics.
For the purposes of paragraph (3), “waste” shall be construed in accordance with Article 2 of the Waste and Contaminated Land (Northern Ireland) Order 1997f1, and shall include any waste disposed of for reprocessing or recycling purposes but shall not include any radioactive waste as defined in section 2 of the Radioactive Substances Act 1993f2.
9Manner of erection and installationI1
Every automatic catchweigher shall be so positioned as to facilitate cleaning and testing.
The installation of an automatic catchweigher shall be so designed that an automatic weighing operation will be the same for testing as for use for a transaction.
If any special equipment for an automatic catchweigher, as referred to in paragraph 9(5) of Schedule 1 to the 2006 Regulations, is not a permanent fixture of the instrument it shall be kept in the vicinity of the instrument.
Signature
Sealed with the Official Seal of the Department of Enterprise, Trade and Investment on 31 August 2007.
L.S.
M. Bohill
A senior officer of the Department of Enterprise, Trade and Investment
Explanatory note
(This note is not part of the Regulations.)
These Regulations set out the requirements relating to the use for trade of automatic catchweighers, the manner of their use and the way they are erected and installed. Failure to comply with these requirements is an offence under Article 13(1) of the Weights and Measures (Northern Ireland) Order 1981.
The Regulations have been notified to the European Commission in draft pursuant to Directive 98/34/EC (O.J. No. L204, 21.7.1998, p. 37) as amended by Directive 98/48/EC (O.J. No. L217, 5.8.1998, p.18) which lays down a procedure for the provision of information in the field of technical standards and regulations.