OpenLegislation

Regulation 5 Maximum permissible errorsI1

Northern Ireland

(1)

An instrument which falls within an accuracy class of 0.3, 0.5 or 1.0 shall, when used to measure a quantity set out in column 1 of the following Table, operate within the maximum permissible error as set out in column 2, 3 or 4 of that Table (as appropriate) for that class and that quantity.

(2)

In that Table, MMQ has the same meaning as minimum measured quantity.

Table

Accuracy Class
0.30.51.0
Column 1Column 2Column 3Column 4
Quantity deliveredMaximum permissible errorMaximum permissible errorMaximum permissible error
MMQ to and including MMQ x 2± 0.6% x MMQ± 1% x MMQ± 2% x MMQ
>MMQ x 2± 0.3% x quantity delivered± 0.5% x quantity delivered± 1% x quantity delivered

Annotations

Commencement

I1

Reg. 5 in operation at 15.10.2007, see reg. 1