OpenLegislation

Paragraph 12 Manner of use

(1)

Where a measuring system is marked with—

(a)

a temperature range, it must not be used for trade in temperatures outside that range; or

(b)

a flowrate range, it must not be used for trade at a flowrate outside that range.

(2)

A measuring system which bears a mark which signifies the manner and purpose of use must not be used for trade in a manner or for a purpose which does not accord with that marking.

(3)

If a measuring system is adjusted, it must not be used for trade unless the calibration of the system is set as close to zero error as is practicable.

(4)

A measuring system must not be used for trade unless it is fitted with a ticket printing mechanism which provides an individual printed ticket.

(5)

A measuring system must not be used for trade in circumstances which are likely prematurely to degrade its metrological characteristics.

(6)

A measuring system must not be used for trade unless the sales indicator—

(a)

is set to zero before measurement of the liquid fuel commences;

(b)

remains at zero until that fuel starts to emerge from the instrument;

(c)

is not reset to zero during measurement of that fuel; and

(d)

cannot be advanced by any means other than by the discharge of that fuel from the instrument and the proper operation of instrument.

(7)

A measuring system must not be used in circumstances—

(a)

which are likely prematurely to degrade its metrological characteristics; or

(b)

in which it may be prevented from operating consistently or accurately.