Paragraph 3 Maximum permissible error
Where a cold-water meter is used for trade within a flowrate range set out in column 1 of the following Table, it must operate within the maximum permissible error specified for that flowrate range set out in column 2 of that Table.
| Column 1 | Column 2 |
|---|---|
| Flowrate range | Maximum permissible error as a percentage of quantity delivered |
| Q1 to ˂ Q2 | ± 6% |
| Q2 to and including Q4 | ± 2.5% |
For the purposes of that Table—
“Q1” is the lowest flowrate at which the cold-water meter provides indications that satisfy the requirements concerning the maximum permissible errors;
“Q2” is the flowrate value occurring between the permanent and minimum flowrates, at which the flowrate range is divided into two zones, the upper zone and the lower zone, each zone having a characteristic maximum permissible error;
“Q3” is the permanent flowrate; and
“Q4” is the highest flowrate at which the cold-water meter operates in a satisfactory manner.