Regulation 35 Fire extinguishersI1
United Kingdom
Non-portable foam, carbon dioxide and dry powder fire extinguishers provided in compliance with these Regulations shall be of approved types and designs and shall meet the requirements of Schedules 2, 3 and 4 of Merchant Shipping Notice MSN 1665.
Portable fire extinguishers provided in compliance with these Regulations shall be of approved types and designs and shall meet the requirements set out in Schedule 8 of Merchant Shipping Notice MSN 1665.
Every fire extinguisher provided in compliance with these Regulations shall be kept fully charged at all times.
Spared charges shall be provided to the extent of at least 50 per cent for each type of fire extinguisher provided in compliance with these Regulations, except for each such fire extinguisher which is of a type that cannot readily be recharged while the ship is at sea, an additional portable fire extinguisher of the same type, or its equivalent, shall be provided in lieu of a spare charge.