Paragraph 20 Planned maintenanceI1
United Kingdom
In relation to planned maintenance—
that the company has specific standing orders, with a planned maintenance system, for all safety related areas including bow and stern doors and side openings, together with their closing arrangements, but also covering engine room maintenance and safety equipment;
that there are plans in place for periodically checking all items so as to maintain safety standards at the highest level;
that there are procedures in place for recording deficiencies and confirming that they have been properly rectified within a time specified commensurate with the severity of the defect so that the master and the designated person ashore within the company management structure can both be made aware of the deficiencies and are notified when those deficiencies have been rectified;
that periodic checking of the operation of the inner and outer bow door closing arrangements includes the indicators, surveillance equipment and any scuppers in the spaces between the bow visor and the inner door and especially the closing mechanisms and their associated hydraulic systems.
Annotations
Commencement
- I1
Sch. 3 para. 20 in force at 5.10.2023, see reg. 1(1)