OpenLegislation

Paragraph 3.1 Construction

Original text. Later amendments are not shown.

A hydrostatic release unit used in the float-free arrangements shall be so constructed that:

3.1.1

the materials used are compatible so as to prevent malfunction of the unit; galvanising or other forms of metallic coating on parts of the release unit will not be accepted;

3.1.2

it has drains to prevent the accumulation of water in the hydrostatic chamber when the unit is in its normal position;

3.1.3

each part connected to the painter system has a strength not less than that required by the painter;

3.1.4

it can readily be removed for replacement or annual servicing.