Paragraph 3.1 Construction
A hydrostatic release unit used in the float-free arrangements shall be so constructed that:
3.1.1
the materials used are compatible so as to prevent malfunction of the unit; galvanising or other forms of metallic coating on parts of the release unit will not be accepted;
3.1.2
it has drains to prevent the accumulation of water in the hydrostatic chamber when the unit is in its normal position;
3.1.3
each part connected to the painter system has a strength not less than that required by the painter;
3.1.4
it can readily be removed for replacement or annual servicing.