Fire-resisting Bulkheads Fire-resisting Bulkheads
United Kingdom
Ships shall be fitted above the bulkhead deck with fire-resisting bulkheads which shall be continuous from side to side of the ship and arranged to the satisfaction of the Administration.
They shall be constructed of metal or other fire-resisting material effective to prevent for one hour, under the conditions for which the bulkheads are to be fitted in the ship, the spread of fire generating a temperature of 1,500°F. (815°C.) at the bulkhead.
Steps and recesses and the means for closing all openings in these bulkheads shall be fire-resisting and flametight.
The mean distance between any two adjacent fire-resisting bulkheads in any superstructure shall in general not exceed 131 feet (40 metres).
Notes on Schedule FIRST
Textual amendments
- F1
Sch. 1 repealed (1.1.1996) by 1995 c. 21, ss. 314(1), 316(2), Sch. 12 (with s. 312(1), Sch. 14 para. 1)