OpenLegislation

Paragraph 54 Minimum performance characteristicsF1

(1)

For the purpose of paragraph 53(a), a method of analysis for a parameter specified in the first column of the table in Section 4 (minimum performance characteristics for a method of analysis) is a method of analysis that complies with minimum performance characteristics if it is a method of analysis that—

(a)

is capable of measuring values equal to the parametric concentration of that parameter with a limit of quantification of 30% or less of the relevant parametric concentration,

(b)

has an uncertainty of measurement that does not exceed the percentage of the parametric concentration for the parameter specified in the second column of the table in Section 4, as read with any further provision relating to the calculation of the uncertainty of measurement specified in the third column of the table, and

(c)

in the case of total organic carbon, complies with the requirement specified in the fourth column of the table.

(2)

For the purpose of sub-paragraph (1)(b), the performance criterion for uncertainty of measurement (k = 2) for a parameter specified in the first column of the table in Section 4 is not less than the percentage specified in the second column of the table of the concentration or value for the parameter specified in the second column of the table in Section 1.

(3)

A method of analysis for hydrogen ion concentration pH is a method of analysis that complies with minimum performance characteristics if it is a method of analysis that—

(a)

is capable of measuring hydrogen ion concentration pH equal to 4.5 pH with a limit of quantification of 30% or less, and

(b)

has an uncertainty of measurement that does not exceed 0.2 of a pH unit.

(4)

For the purpose of sub-paragraph (3)(b), the performance criterion for uncertainty of measurement (k = 2) for hydrogen ion concentration pH is not less than 0.2 of a pH unit.

(5)

Unless otherwise specified in the third column of the table in Section 4, food authorities must estimate uncertainty of measurement for a parameter specified in the first column of the table at the level of the concentration for the parameter specified in the second column of the table in Section 1.

(6)

Where a method of analysis that complies with the requirements of sub-paragraph (1) is used to determine whether the concentration of a parameter specified in the first column of the table in Section 4 exceeds the concentration specified for that parameter in the second column of the table in Section 1, the result of the analysis carried out using that method of analysis must be expressed using at least the same number of significant figures as the number of significant figures used to specify that parametric concentration in the second column of the table in Section 1.

Annotations

Textual amendments

F1

Sch. 12 inserted (6.4.2018) by The Natural Mineral Water, Spring Water and Bottled Drinking Water (England) (Amendment) Regulations 2018 (S.I. 2018/352), reg. 1(1), Sch. 2