OpenLegislation

Parametric concentrations and values for indicator parameters Parametric concentrations and values for indicator parametersF1

ParameterParametric concentration or value

Units of

measurement

Further provisionAdditional requirements
Aluminium200µg/l
Ammonium0.50mg/l
Chloride250mg/lThe water must not be aggressive.
Clostridium perfringens and spores of Clostridium perfringens0number/100mlThis parameter only needs to be checked if the water originates from, or is influenced by, surface water.
ColourAcceptable to consumers and no abnormal change
Conductivity2,500µS cm-1 at 20°CThe water must not be aggressive.
Hydrogen ion concentration9.5pH units

The pH of the water must not be lower than 4.5.

The water must not be aggressive.

Iron200µg/l
Manganese50µg/l
OdourAcceptable to consumers and no abnormal change
Oxidisability5.0mg/l O2This parameter does not need to be checked if total organic carbon is analysed.
Sulphate250mg/lThe water must not be aggressive.
Sodium200mg/l
TasteAcceptable to consumers and no abnormal change
Colony Count 22° CNo abnormal change
Coliform bacteria0number/250ml
Total organic carbonNo abnormal changeThis parameter does not need not be checked for supplies of less than 10,000m3 a day.
TurbidityAcceptable to consumers and no abnormal change

Annotations

Textual amendments

F1

Sch. 12 inserted (6.4.2018) by The Natural Mineral Water, Spring Water and Bottled Drinking Water (England) (Amendment) Regulations 2018 (S.I. 2018/352), reg. 1(1), Sch. 2