OpenLegislation

Part 2 F1

(1)

This table includes values for the most common natural and artificial radionuclides; these are precise values, calculated for a dose of 0.1 mSv, an annual intake of 730 litres and using the dose coefficients laid down in Table A of Annex III to Directive 96/29; derived concentrations for other radionuclides can be calculated on the same basis, and values can be updated on the basis of more recent information recognised by the competent authorities in the Member State.

(2)

This table allows only for the radiological properties of uranium, not for its chemical toxicity.

Methods of analysis and performance characteristicsf1
Table 1
Derived concentrations for radioactivity in spring water or bottled drinking water
OriginNuclideDerived concentration
NaturalU-238f23.0 Bq/l
U-2342.8 Bq/l
Ra-2260.5 Bq/l
Ra-2280.2 Bq/l
Pb-2100.2 Bq/l
Po-2100.1 Bq/l
ArtificialC-14240 Bq/l
Sr-904.9 Bq/l
Pu-239/Pu-2400.6 Bq/l
Am-2410.7 Bq/l
Co-6040 Bq/l
Cs-1347.2 Bq/l
Cs-13711 Bq/l
I-1316.2 Bq/l

Table 2

Performance characteristics and methods of analysis

(1)

The limit of detection is calculated according to the ISO standard 11929: Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionising radiation – Fundamentals and application, with probabilities of errors of 1st and 2nd kind of 0.05 each.

(2)

Measurement uncertainties are calculated and reported as complete standard uncertainties, or as expanded standard uncertainties with an expansion factor of 1.96, according to the ISO Guide for the Expression of Uncertainty in Measurement.

(3)

The limit of detection for tritium and for radon is 10% of its parametric value of 100 Bq/l.

(4)

The limit of detection for gross alpha activity and gross beta activities are 40% of the screening values of 0.1 and 1.0 Bq/l respectively.

(5)

This limit of detection applies only to initial screening for ID for a new water source. If initial checking indicates that it is not plausible that Ra-228 exceeds 20% of the derived concentration, the limit of detection may be increased to 0.08 Bq/l for routine Ra-228 nuclide specific measurements, until a subsequent re-check is required.

Parameters radionuclidesLimit of detectionf3f4
Tritium10 Bq/lf5
Radon10 Bq/l

gross alpha activity

gross beta activity

0.04 Bq/lf6

0.4 Bq/l

U-2380.02 Bq/l
U-2340.02 Bq/l
Ra-2260.04 Bq/l
Ra-2280.02 Bq/lf7
Pb-2100.02 Bq/l
Po-2100.01 Bq/l
C-1420 Bq/l
Sr-900.4 Bq/l
Pu-239/Pu-2400.04 Bq/l
Am-2410.06 Bq/l
Co-600.5 Bq/l
Cs-1340.5 Bq/l
Cs-1370.5 Bq/l
I-1310.5 Bq/l

Annotations

Textual amendments

F1

Sch. 13 inserted (28.11.2015) by The Natural Mineral Water, Spring Water and Bottled Drinking Water (Scotland) Amendment Regulations 2015 (S.S.I. 2015/363), regs. 1, 5

Footnotes

f1

(1)

This table includes values for the most common natural and artificial radionuclides; these are precise values, calculated for a dose of 0.1 mSv, an annual intake of 730 litres and using the dose coefficients laid down in Table A of Annex III to Directive 96/29; derived concentrations for other radionuclides can be calculated on the same basis, and values can be updated on the basis of more recent information recognised by the competent authorities in the Member State.

f2

(2)

This table allows only for the radiological properties of uranium, not for its chemical toxicity.

f3

(1)

The limit of detection is calculated according to the ISO standard 11929: Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionising radiation – Fundamentals and application, with probabilities of errors of 1st and 2nd kind of 0.05 each.

f4

(2)

Measurement uncertainties are calculated and reported as complete standard uncertainties, or as expanded standard uncertainties with an expansion factor of 1.96, according to the ISO Guide for the Expression of Uncertainty in Measurement.

f5

(3)

The limit of detection for tritium and for radon is 10% of its parametric value of 100 Bq/l.

f6

(4)

The limit of detection for gross alpha activity and gross beta activities are 40% of the screening values of 0.1 and 1.0 Bq/l respectively.

f7

(5)

This limit of detection applies only to initial screening for ID for a new water source. If initial checking indicates that it is not plausible that Ra-228 exceeds 20% of the derived concentration, the limit of detection may be increased to 0.08 Bq/l for routine Ra-228 nuclide specific measurements, until a subsequent re-check is required.