An ozone-enriched air treatment must not—

(a)

modify the physico-chemical composition of the water in terms of its characteristic constituents; or

(b)

leave residues in the water which could pose a risk to public health, or, in the case of the substances listed below, above the levels specified.

Treatment residueMaximum limit ug/l
Dissolved ozone50
Bromate3
Bromoform1