Schedule I1
United Kingdom
| Type of equipment | Net installed power P (in kW) Electric power Pel f1 in kW Mass of appliance m in kg Cutting width L in cm | Permissible sound power level in dB/1 pW | |
|---|---|---|---|
| Stage I as from 3 January 2002 | Stage II as from 3 January 2006 | ||
a Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2. | |||
b For the following types of equipment the figures for Stage I shall continue to apply for Stage II—
| |||
c For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply. | |||
| Compaction machines (vibrating rollers, vibratory plates, vibratory rammers) | P ≤ £ 8 | 108 | 105f2 |
| 8 < P ≤ £70 | 109 | 106 | |
| P > 70 | 89 + 11 1g P | 86 + 11 1g P | |
| Tracked dozers, tracked loaders, tracked excavator-loaders | P ≤ 55 | 106 | 103 |
| P > 55 | 87 + 11 1g P | 84 + 11 1g P | |
| Wheeled dozers,wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, compaction machines (non-vibrating rollers),paver-finishers, hydraulic power packs | P ≤ 55 | 104 | 101 |
| P > 55 | 85 + 11 1g P | 82 + 11 1g P | |
| Mobile cranes | P ≤ 55 | 104 | 101f3 |
| P > 55 | 85 + 11 1g P | 82 + 11 1g P 101 | |
| Excavators, builders' hoists for the transport of goods, construction winches, motor hoes | P ≤ 15 | 96 | 93 |
| P > 15 | 83 + 11 1g P | 80 + 11 1g P | |
| Hand-held concrete-breakers and picks | m ≤ 15 | 107 | 105 |
| 15< m < 30 | 94 + 11 1g m | 92 + 11 1g m | |
| m ≥ 30 | 96 + 11 1g m | 94 + 11 1g m | |
| Tower cranes | 98 + 1g P | 96 + 1g P | |
| Welding and power generators | Pel ≤ 2 | 97 + 1g Pel | 95 + 1g Pel |
| 2 < Pel ≤ 10 | 98 + 1g Pel | 96 + 1g Pel | |
| 10 > Pel | 97 + 1g Pel | 95 + 1g Pel | |
| Compressors | P ≤ 15 | 99 | 97 |
| P > 15 | 97 + 2 1g Pel | 95 + 2 1g Pel | |
| Lawnmowers, lawn trimmers/lawn-edge trimmers | L ≤ 50 | 96 | 96 |
| 50 < L ≤ 70 | 100 | 98 | |
| 70 < L ≤ 120 | 100 | 100 | |
| L > 120 | 105 | 105 | |
| The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0.5, use lower number; greater than or equal to 0.5, use higher number). | |||
Annotations
Commencement
- I1
Sch. in force at 3.1.2006, see reg. 1
Footnotes
- f1
a
Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2.
- f2
b
For the following types of equipment the figures for Stage I shall continue to apply for Stage II—
-
Walk-behind vibrating rollers;
-
Vibratory plates (>3 kW);
-
Vibratory rammers;
-
Dozers (steel tracked);
-
Loaders (steel tracked >55 kW);
-
Combustion-engine driver counterbalanced lift trucks;
-
Compacting screed paver-finishers; and
-
Hand-held internal combustion-engine concrete-breakers and picks (15< m<30).
-
- f3
c
For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply.