OpenLegislation

Paragraph 2.2.3 F1

For instruments with auxiliary indicating devices the following conditions apply—

  • e = 1 x 10kg;

  • d < e ≤ 10 d.

Those conditions do not apply for instruments of class I with d < 10–4 g, for which e = 10–3 g.

Annotations

Textual amendments

F1

Schs. 6-9 inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 26 para. 45 (with Sch. 26 para. 5) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)