Paragraph 3.3.3 F1
The partial weighing ranges are classified according to Table 2. All partial weighing ranges shall fall into the same accuracy class, that class being the instrument's accuracy class.
Table 2
| Multi-level instruments | ||||
|---|---|---|---|---|
i = 1, 2, …r, i = partial weighing range number, r = the total number of partial weighing ranges | ||||
| Class | Verification scale interval (e) | Minimum capacity (Min) | Number of verification scale intervals | |
| Minimum value | Minimum value F2 n = ((Maxi) / (e(i+1))) | Maximum value n = ((Maxi) / (ei)) | ||
| I | 0,001 g ≤ ei | 100 e1 | 50 000 | |
| II | 0,001 g ≤ ei ≤ 0,05 g | 20 e1 | 5 000 | 100 000 |
| 0,1 g ≤ ei | 50 e1 | 5 000 | 100 000 | |
| III | 0,1 g ≤ ei | 20 e1 | 500 | 10 000 |
| IIII | 5g ≤ ei | 10 e1 | 50 | 1 000 |
Annotations
Textual amendments
- F1
Schs. 6-9 inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 26 para. 45 (with Sch. 26 para. 5) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)
- F2
For I = r, the corresponding column of Table 1 applies, with e replaced by er.