Paragraph 4.2 Specifications concerning the emissions of pollutants
The gaseous and particulate components emitted by the engine submitted for testing shall be measured by the methods described in Annex V.
-
Other systems or analysers may be accepted if they yield equivalent results to the following reference systems:
-
for gaseous emissions measured in the raw exhaust, the system shown in Figure 2 of Annex V,
-
for gaseous emissions measured in the dilute exhaust of a full flow dilution system, the system shown in Figure 3 of Annex V,
-
for particulate emissions, the full flow dilution system, operating with a separate filter for each mode or with the single filter method, shown in Figure 13 of Annex V.
-
-
The determination of system equivalency shall be based upon a seven test cycle (or larger) correlation study between the system under consideration and one or more of the above reference systems.
-
The equivalency criterion is defined as a ±5% agreement of the averages of the weighted cycle emissions values. The cycle to be used shall be that given in Annex III, section 3.6.1.
-
For introduction of a new system into the Directive the determination of equivalency shall be based upon the calculation of repeatability and reproducibility, as described in ISO 5725.