Paragraph 4 Sampling equipmentI1
Northern Ireland
The Department shall only use sampling bottles which—
have been—
sterilised in an autoclave for at least 15 minutes at 121 degrees Celsius;
dry sterilised at no lower than 160 degrees Celsius and no higher than 170 degrees Celsius for at least one hour; or
irradiated by their manufacturer and not used previously;
are of a size which allows sufficient water to be taken and analysed for the presence of Intestinal enterococci and Escherichia coli; and
are made of transparent and colourless material.
The Department shall—
use aseptic techniques to maintain the sterility of the sample bottles; and
clearly identify every sample taken by marking in indelible ink the sample bottle and associated paperwork.