Paragraph 15 Wall thickness
If the product of PS x V is not more than 3 000 bar.L, the manufacturer must select one of the methods described in paragraphs 16 (calculation method) and 17 (experimental method) for determining vessel wall thickness.
If the product of PS x V is more than 3 000 bar.L, or if the maximum working temperature exceeds 100°C, such thickness must be determined by the method described in paragraph 16 (calculation method).
The actual wall thickness of the cylindrical section and ends must, however, be not less than 2 mm in the case of steel vessels and not less than 3 mm in the case of aluminium or aluminium alloy vessels.
Notes on the whole SI
Textual amendments
- F1
- F2
1972 c.68. Section 2(2) was amended by section 27(1)(a) of the Legislative and Regulatory Reform Act 2006 (c.51) and by Part 1 of the Schedule to the European Union (Amendment) Act 2008 (c.7). The enabling powers of section 2(2) were extended by virtue of the amendment of section 1(2) by section 1 of the European Economic Area Act 1993 (c.51).
- F3