OpenLegislation

Schedule I1F1

England, Wales and Scotland

Class of fireplaceConditions

The Intrepid II woodstove manufactured by Vermont Castings, Inc.

1

The fireplace shall be installed, maintained and operated in accordance with the manufacturer’s instructions bearing the reference “AMENDED No. 20917C U.K. MAY 1990”.

2

No fuel shall be used other than 16" firewood that has been split, stacked and air-dried.

The Spacewarmer B200 manufactured by Clearair Limited.

1

The fireplace shall be installed, maintained and operated in accordance with the manufacturer’s instructions bearing the reference “B200/DEC 83'”.

2

No fuel shall be used other than hardwood or softwood offcuts, a mixture of offcuts (hardwood or softwood) and sawdust with no more than 50% of the mixture being sawdust, chipboard offcuts or plastic coated chipboard offcuts.

3

The fireplace shall not be used to burn chipboard or plastic coated chipboard unless an afterburner, supplied by the manufacturer of the fireplace and capable of producing 50 megajoules of heat per hour, has been fitted to the fireplace.

The Spacewarmer B500 manufactured by Clearair Limited.

1

The fireplace shall be installed, maintained and operated in accordance with the manufacturer’s instructions bearing the reference “B500/DEC 83'”.

2

No fuel shall be used other than hardwood or softwood offcuts.

The “Turbo” Heat, models 1000 and 1200 manufactured by CBR Engineers Limited.

1

The fireplace shall be installed, maintained and operated in accordance with the manufacturer’s instructions bearing the reference “CBR “TURBO” HEAT 1000 TO 1200 1990”.

2

No fuel shall be used other than hardwood or softwood offcuts, chipboard offcuts or plastic coated chipboard offcuts.

The Talbott’s Energy Saving Wood Waste Burning Automatic Warm Air Heaters, models T1.5/A, T3/A, T5/A and TM/A manufactured by Talbotts Heating Limited.

1

The fireplaces shall be installed, maintained and operated in accordance with the manufacturer’s instructions bearing the reference “T/A JANUARY 1990”.

2

No fuel shall be used other than hardwood or softwood shavings or sawdust.

Annotations

Textual amendments

F1

Order revoked (S.) (29.6.2009) by The Smoke Control Areas (Exempt Fireplaces) (Scotland) Order 2009 (S.S.I. 2009/214), arts. 1(1), 3, sch. 2; and revoked (E.) (6.4.2015) by The Smoke Control Areas (Exempted Fireplaces) (England) Order 2015 (S.I. 2015/307), art. 1(c), Sch. 2 Pt. 2

Commencement

I1

Sch. in force at 31.12.1990, see art. 1