Paragraph 46 I1
England, Wales and Scotland
Sub-paragraphs (3) to (7) make provision about how the Standards are to apply.
In relation to the requirements of BS EN 12675:2001, if the state specified in column 2 of an item in table 1 occurs, the class of response that applies is that set out in column 3.
In relation to the requirements of BS EN 50556:2011, the class of response for an aspect of performance at an item in table 2 in column 3 (within a subject area in column 2) is that in column 4.
The signal states which endanger traffic for the purposes of 5.2.3 of BS EN 50556:2011 are those specified in column 2 of table 1 at item 1, 2, 4 or 16.
Upon a state described in sub-paragraph (5) occurring, all signal heads and push button units must switch off in accordance with the classes of response specified in column 4 of table 2 at items 6 and 7.
Table 1:
Requirements of BS EN 12675:2001
(1) Item | (2) State | (3) Class |
|---|---|---|
| 1 | Green-green conflict | AA1 |
| 2 | Green-yellow conflict | AB1 |
| 3 | Yellow-yellow conflict | AC0 |
| 4 | Green-red/yellow conflict | AD1 |
| 5 | Green-green/yellow conflict | AE0 |
| 6 | Absence of any conflicting red signal | AF0 |
| 7 | Absence for conflicting red on specified signal heads | AG0 |
| 8 | Absence of the last conflicting red signal | AH0 |
| 9 | Absent red/absent red | AJ0 |
| 10 | National signal regulations (infringement) | BA0 |
| 11 | Absence of a red signal on a specified signal group | CA1 |
| 12 | Absence of the last red signal | CB1 |
| 13 | Absence of a number of red signals | CC1 |
| 14 | Absence of specified red signals | CD0 |
| 15 | Absent signal groups, yellow or green signals | CE0 |
| 16 | Compliance checking | DA1 |
| 17 | Stored values of timings | FA1 |
| 18 | Time base frequency | FB0 |
| 19 | Minimum values of time settings | FC0 |
| 20 | Maximum values of time settings | FD0 |
| 21 | Duration of timings | FE0 |
| 22 | National signal sequences (infringement) | GA0 |
| 23 | Specified signal group green to signal group green movements | GB0 |
| 24 | Specified signal start-up sequence signal group movements | GC0 |
| 25 | Failure of external inputs | HA1 |
Table 2:
Requirements of BS EN 50556:2011
(1) Item | (2) Subject area | (3) Aspect of performance | (4) Class |
|---|---|---|---|
| 1 | Electrical supply | Overvoltage | D0 |
| 2 | Safety | Leakage current | T2 |
| 3 | Enclosure | V2 | |
| 4 | Terminations | H0 | |
| 5 | Requirements of signalling intensity for safety | AF5 | |
| 6 | Requirements for signal states (i) | AG5 | |
| 7 | Requirements for signal states (ii) | X1 | |
| 8 | Location of monitoring elements for signals | N0 | |
| 9 | Test of impedance | Fault loop impedance test | AA1 |
| 10 | Maintenance | Maintenance testing procedures | Y1 |
| 11 | Environmental | Dry heat | AB3 |
| 12 | Cold | AE2 | |
| 13 | Damp heat, cyclic | AK2 | |
| 14 | Solar radiation | AH0 | |
| 15 | Random vibration (operational) | AL2 | |
| 16 | Random vibration (transportation) | AM2 |