(1)

Every unvented water heater, not being an instantaneous water heater with a capacity not greater than 15 litres, and every secondary coil contained in a primary system shall–

(a)

be fitted with F1a temperature control device and either a temperature relief valve or a combined temperature and pressure relief valve; or

(b)

be capable of accommodating expansion within the secondary hot water system.

(2)

An expansion valve shall be fitted with provision to ensure that water is discharged in a correct manner in the event of a malfunction of the expansion vessel or system.