OpenLegislation

Schedule 5 Analytical methodology

England and Wales

F1Table A1

Microbiological parameters for which, subject to regulation 16(6), methods of analysis are specified

(1) Parameter(2) Method of analysis
E. coli and coliform bacteriaEN ISO 9308-1 or EN ISO 9308-2
EnterococciEN ISO 7899-2
Pseudomonas aeruginosaEN ISO 16266
Enumeration of culturable microorganisms – colony count 22°cEN ISO 6222
Enumeration of culturable microorganisms – colony count 36°cEN ISO 6222
Clostridium perfringens (including spores)EN ISO 14189

Table A2

F2 . . . . . . . . . . . .

F3Table A3

Minimum performance characteristic uncertainty of measurement

The uncertainty of measurement laid down in this table must not be used as an additional tolerance to the parmetric value set out in Schedules 1 and 2.

(1) Parameters(2) Uncertainty of measurement % of the parametric value (except for pH)
(1)

“Uncertainty of measurement” is a non-negative parameter characterising the dispersion of the quantity values being attributed to a measurement, based on the information used. The performance criterion for measurement uncertainty (k = 2) is at least the percentage of the parametric value stated in the table.

(2)

If the value of uncertainty of measurement cannot be met, the best available technique must be selected (up to 60% of the parametric value).

(3)

The method determines total cyanide in all forms.

(4)

Reference method: European standard EN ISO 8467 entitled “Water quality – Determination of permanganate index (ISO 8467)”.

(5)

The performance characteristics for individual pesticides are given as an indication. Values for the uncertainty of measurement as low as 30% can be achieved for several pesticides, higher values up to 80 % may be allowed for a number of pesticides.

(6)

The performance characteristics apply to individual substances, specified at 25% of the parametric value in Part I of Table B in Schedule 1.

(7)

The performance characteristics apply to individual substances, specified at 50% of the parametric value in Part I of Table B in Schedule 1.

(8)

The uncertainty of measurement must be estimated at the level of 3 mg/l of the total organic carbon (TOC) in accordance with European standard EN 1484 entitled “Water analysis – Guidelines for the determination of total organic carbon and dissolved organic carbon”.

(9)

The uncertainty of measurement must be estimated at the level of 1.0 nephelometric turbidity units) in accordance with European standard EN ISO 7027-1 entitled “Water quality – Determination of turbidity – Part 1: Quantitative methods (ISO 7027-1”.

Aluminium25
Ammonium40
Antimony40
Arsenic30
Benzene40
Benzo(a)pyrene 50
Boron25
Bromate40
Cadmium25
Chloride15
Chromium30
Colour20
Conductivity20
Copper25
Cyanide 30
1,2-dichloroethane40
Fluoride20
Hydrogen ion concentration pH (expressed in pH units)0.2
Iron30
Lead25
Manganese30
Mercury30
Nickel25
Nitrate15
Nitrite20
Oxidisability 50
Pesticides 30
Polycyclic aromatic hydrocarbons 50
Selenium40
Sodium15
Sulphate15
Tetrachloroethene 30
Tetrachloromethane30
Trichloroethene 40
Trihalomethanes: total 40
Total organic carbon 30
Turbidity 30

Annotations

Textual amendments

F1

Sch. 5 Table A1 substituted (11.7.2018) by The Water Supply (Water Quality) (Amendment) Regulations 2018 (S.I. 2018/706), regs. 1(1), 2(15)(a) (with reg. 3)

F2

Sch. 5 Table A2 omitted (11.7.2018) by virtue of The Water Supply (Water Quality) (Amendment) Regulations 2018 (S.I. 2018/706), regs. 1(1), 2(15)(b) (with reg. 3)

F3

Sch. 5 Table A3 and footnotes inserted (11.7.2018) by The Water Supply (Water Quality) (Amendment) Regulations 2018 (S.I. 2018/706), regs. 1(1), 2(15)(c) (with reg. 3)