OpenLegislation

Paragraph

The maximum permissible error for any load equal to or greater than the minimum capacity (Min) and equal to or less than the maximum capacity (Max) in automatic operation shall be as specified in Table 1. (Note that the mpe-value includes the digital rounding error of the indicating device.)

Table 1

Load (m) expressed in verification scale intervals (e)Maximum permissible error for class Y(y) instruments
Class Y(a)Class Y(b)Initial verificationIn-service
0<m �?� 5000<m �?� 50±1.5 e±2 e
500<m �?� 2,00050<m �?� 200±2 e±3 e
2,000<m �?�10,000200<m �?�1,000±2.5 e±4 e