OpenLegislation

Paragraph 9

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

(1)

After allowing the machine to weigh and discharge suitable material for at least five fillings of the load receptor by the normal automatic process, the process shall be stopped with the load receptor empty and the inspector shall:—

(a)

using the subdivided scale, ensure that the individual weight indicating device is set to zero or a given point; and

(b)

set the totalisation indicating device to zero.

(2)

The automatic processing of material shall then be interrupted when the load receptor is loaded and ready to be discharged, the inspector, shall note the individual weight value indicated and then allow the material to be discharged by the automatic process.

(3)

When the load receptor is emptied the weighing process shall again be interrupted and the indicated weight value noted; the inspector shall then determine the true net weight of material discharged, taking account of any appropriate errors of the weighing unit obtained from the calibration chart or graph.

(4)

The inspector shall then:

(a)

determine the total true net weight of a group of 20 separate loads in accordance with sub-paragraphs (2) and (3); and

(b)

record the corresponding value of that weight of material indicated by the totalisation indicating device.

(5)

The total net weight of a minimum of two groups of 20 separate loads shall be determined with at least two of the groups consisting of tests involving the weighing on the machine of approximately the same quantity of suitable material, at least equal to the minimum totalised load marked on the machine.

(6)

Where the quantity of material weighed by the machine can vary, each group of tests referred to in sub-paragraph (5) shall be made with a quantity of suitable material as nearly as practicable equal to the minimum totalised load and another test consisting of a group of 20 separate loads with a quantity of suitable material as nearly as practicable equal to the maximum capacity shall then be carried out on the machine.

(7)

For each group of tests carried out in accordance with sub-paragraphs (4), (5) and (6), the inspector shall determine the material test error by ascertaining the difference between the weight of material determined in accordance with sub-paragraph (4)(a) and the value for that weight of material obtained from the totalisation indicating device in accordance with sub-paragraph (4)(b).

(8)

Subject to sub-paragraph (9), the inspector shall determine the repeatability error for each of the group of tests carried out in accordance with sub-paragraph (5), being the difference between the material testing errors determined in accordance with sub-paragraph (7).

(9)

Before 1st January 1988, the inspector shall not carry out his duties specified in sub-paragraph (8) in respect of any discontinuous totaliser which is made in accordance with a pattern in respect of which a certificate of approval was in force before the date of coming into operation of these Regulations.