Paragraph 11 I1
England, Wales and Scotland
The specifications for non-graduated and graduated Class I machines are given in Table 1.
Table 1
| Maximum capacity “Max” | Lower limit ofthe minimum load “Min” | Scale interval “d” | Number of scale intervals “n” | Verification scale interval “e” |
|---|---|---|---|---|
Notes
| ||||
| Non-graduated machines | ||||
| 100 mg ≤ Max ≤ 1 g | 10 e | 0.1 mg | ||
| 1 g < Max < 10 g | 50 e | |||
| 10 g ≤ Max < 100 g | 50 e | 1 mg | ||
| 100 g ≤ Max | 50 e | |||
| Graduated machines | ||||
| 0.5 mg ≤ Max | d | d ≤ 0.005 mg | 10 ≤ n | d |
| 1 mg ≤ Max | 10 d | 0.01 mg ≤ d ≤ 0.05 mg | 100 ≤ n | d |
| 10 mg ≤ Max | 50 d | 0.1 mg ≤ d ≤ 0.5 mg | 100 ≤ n | d |
| 100 g ≤ Max | 50 d | 1 mg ≤ d | 100 000 ≤ n | d |
Annotations
Commencement
- I1
Sch. 1 para. 11 in force at 2.5.2000, see reg. 1(1)