Paragraph 11 I1
Northern Ireland
The specifications for non-graduated and graduated Class I machines are given in Table 1.
Table 1
| Maximum capacity“Max” | Lower limit of the minimum load“Min” | Scale interval“d” | Number of scale intervals“n” | Verification scale interval“e” |
|---|---|---|---|---|
| Non-graduated machines | ||||
| 100 mg ≤ Max | 10 e | 0.1 mg | ||
| ≤ 1 g | ||||
| 1 g ≤ Max | 50 e | Max | ||
| <10 g | … | |||
| 10 000 | ||||
| 10 g ≤ Max | 50 e | 1 mg | ||
| <100 g | ||||
| 100 g ≤ Max | 50 e | Max | ||
| … | ||||
| 100 000 | ||||
| Graduated machines | ||||
| 0.5 mg ≤ Max | d | d ≤ 0.005 mg | 10 ≤ n | d |
| 1 mg ≤ Max | 10 d | 0.01 mg ≤ d | 100 ≤ n | d |
| ≤ 0.05 mg | ||||
| 10 mg ≤ Max | 50 d | 0.1 mg ≤ d | 100 ≤ n | d |
| ≤ 0.5 mg | ||||
| 100 g ≤ Max | 50 d | 1 mg ≤ d | 100 000 ≤ n | d |
Annotations
Commencement
- I1
Sch. 1 para. 11 in operation at 13.2.2006, see reg. 1(1)