OpenLegislation

Paragraph 11 I1

Northern Ireland

The specifications for non-graduated and graduated Class I machines are given in Table 1.

Table 1

Maximum capacity“Max”Lower limit of the minimum load“Min”Scale interval“d”Number of scale intervals“n”Verification scale interval“e”
Non-graduated machines
100 mg ≤ Max10 e0.1 mg
≤ 1 g
1 g ≤ Max50 eMax
<10 g…
10 000
10 g ≤ Max50 e1 mg
<100 g
100 g ≤ Max50 eMax
…
100 000
Graduated machines
0.5 mg ≤ Maxdd ≤ 0.005 mg10 ≤ nd
1 mg ≤ Max10 d0.01 mg ≤ d100 ≤ nd
≤ 0.05 mg
10 mg ≤ Max50 d0.1 mg ≤ d100 ≤ nd
≤ 0.5 mg
100 g ≤ Max50 d1 mg ≤ d100 000 ≤ nd

Annotations

Commencement

I1

Sch. 1 para. 11 in operation at 13.2.2006, see reg. 1(1)