OpenLegislation

Regulation 16 System gain limitsI1

United Kingdom

(1)

When measured separately for each of the frequency bands being transmitted—

(a)

the uplink and downlink system gain must not exceed whichever is the smaller of—

(i)

100 dB; and

(ii)

10 dB – RSSI; and

(b)

the uplink and downlink system gain must be equal.

(2)

In this regulation, “RSSI” means received signal strength indicator, which is the total downlink signal power received at the donor port of the mobile repeater device, for all base stations in the frequency band being transmitted (and which shall be measured in dBm).

Annotations

Commencement

I1

Reg. 16 in force at 16.6.2022, see reg. 1