Regulation 8 Further requirements relating to generic slave operational parametersI1
United Kingdom
A master device which communicates generic slave operational parameters to a slave device must have requested and received those parameters from a database.
When requesting generic slave operational parameters from a database, a master device must communicate its master device characteristics to that database.
A master device must communicate to the database from which it has received generic slave operational parameters—
the unique identifiers which have been communicated to the master device by slave devices which are transmitting using those parameters; and
the master device’s unique identifier.
A master device must communicate to the database from which it has received generic slave operational parameters—
the channel usage parameters of slave devices that transmit using those parameters and which are either—
channel usage parameters determined by the slave device and communicated to the master device; or
channel usage parameters determined by the master device for that slave device; and
the master device’s unique identifier.
Annotations
Commencement
- I1
Reg. 8 in force at 31.12.2015, see reg. 1(1)