OpenLegislation

Chapter Action levels – non-thermal effects

England, Wales and Scotland

Table AL1 – ALs for exposure to electromagnetic fields from 1 Hz to 10 MHz

Frequency rangeExternal electric field strength Low ALs (E) [Vm-1]External electric field strength High ALs (E) [Vm-1]
1 ≤ f < 25 Hz2.0 × 1042.0 × 104
25 ≤ f < 50 Hz5.0 × 105/f2.0 × 104
50 Hz ≤ f < 1.64 kHz5.0 × 105/f1.0 × 106/f
1.64 ≤ f < 3 kHz5.0 × 105/f6.1 × 102
3 kHz ≤ f ≤ 10 MHz1.7 × 1026.1 × 102
Exposure levels not exceeding the ALs will be compliant with:

Tables ELV2 and ELV3

  1. 1Notes
  2. 2Notes
  3. 3Notes
  4. 1Notes
  5. 2Notes

Notes on Part 2

Commencement

I1