Paragraph 3 Notes

England, Wales and Scotland

The ALs represent the maximum field values at any place where an employee may be working, before the entry of any person into the field. In the case of an electromagnetic field source in the immediate vicinity of the body, compliance with the ELVs must be determined dosimetrically, case by case.

Table AL2 – ALs for exposure to electromagnetic fields from 1 Hz to 10 MHz

Frequency rangeMagnetic flux density Low ALs (B)[µT]Magnetic flux density High ALs (B)[µT]Magnetic flux density ALs for exposure of limbs to a localised magnetic field (B) [µT]
1 ≤ f < 8 Hz2.0 × 105/f23.0 × 105/f9.0 × 105/f
8 ≤ f < 25 Hz2.5 × 104/f3.0 × 105/f9.0 × 105/f
25 ≤ f < 300 Hz1.0 × 1033.0 × 105/f9.0 × 105/f
300 Hz ≤ f < 3 kHz3.0 × 105/f3.0 × 105/f9.0 × 105/f
3 kHz ≤ f ≤ 10 MHz1.0 × 1021.0 × 1023.0 × 102
Exposure levels not exceeding the ALs will be compliant with:At and below 400 Hz: the sensory effect ELVs in Table ELV3The health effect ELVs in Table ELV2
Above 400 Hz: the health effect ELVs in Table ELV2

Notes on Part 2

Commencement

I1

Sch. Pt. 2 in force at 1.7.2016, see reg. 1