OpenLegislation

Paragraph 6 I1

(1)

F1Within Work No. 1A, wind turbine generator foundation structures must be of 1 or more of the following foundation options: monopole, multi-leg or gravity base.

(2)

No wind turbine generator foundation structure employing a footing of driven piles may—

(a)

have more than 6 driven piles;

(b)

in the case of single-pile structures, have a pile diameter exceeding 12 metres or employ a hammer energy during installation exceeding F24,000 kilojoules;

(c)

in the case of structures with 2 or more piles, have a pile diameter exceeding 3.5 metres or employ a hammer energy during installation exceeding 2,300 kilojoules.

(3)

No wind turbine generator foundation may have—

(a)

a main supporting structure exceeding 61 metres in width;

(b)

a seabed footprint (excluding subsea scour protection) exceeding 2,376 square metres;

(c)

a seabed footprint (including subsea scour protection) exceeding 5,675 square metres.

(4)

The foundations for wind turbine generators must be in accordance with the wave reflection co-efficient values set out in Table 3.6 in Chapter 5, Appendix B (foundation characterisation study) of the environmental statement.

Annotations

Textual amendments

F1

Words in Sch. 1 Pt. 3 para. 6(1) substituted (15.1.2021) by The Dogger Bank Teesside A and B Offshore Wind Farm (Amendment) Order 2021 (S.I. 2021/39), arts. 1, 5(b)

F2

Word in Sch. 1 Pt. 3 para. 6(2)(b) substituted (25.1.2021) by The Dogger Bank Teesside A and B Offshore Wind Farm (Amendment) (No. 2) Order 2021 (S.I. 2021/71), arts. 1, 4

Commencement

I1

Sch. 1 Pt. 3 para. 6 in force at 26.8.2015, see art. 1