OpenLegislation

Paragraph 1 Energy efficiency requirementsI1

England, Wales and Scotland

Light sources

(1)

The declared power consumption of a light source Pon must not exceed the maximum allowed power Ponmax (in W), defined as a function of the declared useful luminous flux Φuse (in lm) and the declared colour rendering index CRI (-) as follows—

  • Ponmax = C × (L + Φuse/(F × η)) × R;

where—

(a)

the values for threshold efficacy (η in lm/W) and end loss factor (L in W) are as specified in Table 2, according to the light source type;

(b)

basic values for correction factor (C) depending on light source type, and additions to C for special light source features are specified in Table 3;

(c)

efficacy factor (F) is—

(i)

1.00 for non-directional light sources (NDLS, using total flux);

(ii)

0.85 for directional light sources (DLS, using flux in a cone);

(d)

CRI factor (R) is—

(i)

0.65 for CRI ≤ 25;

(ii)

(CRI+80)/160 for CRI > 25,

rounded to two decimals.

Table 2

Threshold efficacy (η) and end loss factor (L)

Light source descriptionηL
(lm/W)(W)
LFL T5-HE98.81.9
LFL T5-HO, 4,000 ≤ Φ ≤ 5,000 lm83.01.9
LFL T5-HO, other lm output79.01.9
FL T5 circular79.01.9
FL T8 (including FL T8 U-shaped)89.74.5
From 1st September 2023, for FL T8 of 2-, 4- and 5-foot120.01.5
Magnetic induction light source, any length or flux70.22.3
CFLni70.22.3
FL T9 circular71.56.2
HPS single-ended88.050.0
HPS double-ended78.047.7
MH ≤ 405 W single-ended84.57.7
MH > 405 W single-ended79.312.3
MH ceramic double-ended84.57.7
MH quartz double-ended79.312.3
OLED65.01.5
Before 1 September 2023: HL G9, G4 and GY6.3519.57.7
HL R7s ≤ 2 700 lm26.013.0
Connected light sources (CLS) not mentioned above120.02.0
Other light sources not mentioned above120.01.5

Table 3

Correction factor C depending on light source characteristics

Light source typeBasic C value
Non-directional (NDLS) not operating on mains (NMLS)1.00
Non-directional (NDLS) operating on mains (MLS)1.08
Directional (DLS) not operating on mains (NMLS)1.15
Directional (DLS) operating on mains (MLS)1.23
Special light source featureAddition on C
FL or HID with CCT > 5,000K+0.10
FL with CRI > 90+0.10
HID with second envelope+0.10
MH NDLS > 405 W with non-clear envelope+0.10
DLS with anti-glare shield+0.20
Colour-tuneable light source (CTLS)+0.10
High luminance light source (HLLS)+ 0.0058 · Luminance-HLLS – 0.0167
(2)

For the purposes of this paragraph—

(a)

where applicable, additions on correction factor C are cumulative;

(b)

the addition for HLLS must not be combined with the basic C-value for DLS (basic C-value for NDLS must be used for HLLS);

(c)

light sources which allow the end-user to adapt the spectrum and/or the beam angle of the emitted light, resulting in changes to the values for useful luminous flux, colour rendering index (CRI) and/or correlated colour temperature (CCT), and/or changing the directional/non-directional status of the light source, must be evaluated using the reference control settings;

(d)

the standby power Psb of a light source must not exceed 0.5 W;

(e)

the networked standby power Pnet of a connected light source must not exceed 0.5 W;

(f)

the allowable values for Psb and Pnet must not be added together.

(3)

This paragraph is subject to the exemptions in paragraph 3(3) of Schedule 4.

Annotations

Commencement

I1

Sch. 3 para. 1 in force at 1.10.2021, see reg. 1(2)