Paragraph 2 Energy efficiency requirementsI1
England, Wales and Scotland
Separate control gears
The minimum energy efficiency requirements of a separate control gear operating at full-load are the values set out in Table 4.
Table 4
Minimum energy efficiency for separate control gear at full-load
| Declared output power of the control gear (Pcg) or declared power of the light source (Pls) in W, as applicable | Minimum energy efficiency |
|---|---|
Control gear for HL light sources all wattages Pcg | 0.91 |
Control gear for FL light sources Pls ≤ 5 5 < Pls ≤ 100 100 < Pls | 0.71 Pls/(2 × √(Pls/36) + 38/36 × Pls+1) 0.91 |
Control gear for HID light sources Pls ≤ 30 30 < Pls ≤ 75 75 < Pls ≤ 105 105 < Pls ≤ 405 405 < Pls | 0.78 0.85 0.87 0.90 0.92 |
Control gear for LED or OLED light sources all wattages Pcg | Pcg 0.81/(1.09 × Pcg 0.81 + 2.10 ) |
For the purposes of this paragraph, the requirements of Table 4 apply to multi-wattage separate control gears in respect of the maximum declared power on which they can operate.
Where a manufacturer or importer has declared in the technical documentation that a separate control gear has been designed for no-load mode, the no-load power Pno of the control gear must not exceed 0.5W.
The standby power Psb of a separate control gear must not exceed 0.5 W.
For a connected separate control gear—
the networked standby power Pnet must not exceed 0.5 W;
the allowable values for Psb and Pnet must not be added together.
This paragraph is subject to the exemptions in paragraph 3(3) of Schedule 4.
Annotations
Commencement
- I1
Sch. 3 para. 2 in force at 1.10.2021, see reg. 1(2)