OpenLegislation

Article 17 Determining savings for a qualifying boiler repair and replacementI1

England, Wales and Scotland

(1)

The cost saving for the repair or replacement of a qualifying boiler must be determined in accordance with the following formula—

(A−B)×N
(2)

In paragraph (1)—

  • “A” means the cost of heating the premises (“P”) where the repaired or replaced boiler is situated and, where applicable, heating water at P as determined in accordance with—

    1. (a)

      the Standard Assessment Procedure F1or the Standard Assessment Procedure 2012;

    2. (b)

      the Reduced Data Standard Assessment Procedure F2or RdSAP 2012; or

    3. (c)

      an appropriate methodology for calculating the savings approved by the Administrator under article 18,

    where the calculation is based on the absence of a working heating system in P;

  • “B” means the cost of heating P and, where applicable, heating water at P using, as applicable, the boiler that was repaired or the replacement boiler;

  • “N” means—

    1. (a)

      in the case of a repair of a qualifying boiler which is accompanied with—

      1. (i)

        a year’s warranty, 1;

      2. (ii)

        two year’s warranty, 2;

    2. (b)

      in the case of a replacement of a qualifying boiler, 12.

Annotations

Textual amendments

F1

Words in art. 17(2) inserted (1.12.2014) by The Electricity and Gas (Energy Companies Obligation) (Determination of Savings) (Amendment) Order 2014 (S.I. 2014/2897), arts. 1, 5(a)

F2

Words in art. 17(2) inserted (1.12.2014) by The Electricity and Gas (Energy Companies Obligation) (Determination of Savings) (Amendment) Order 2014 (S.I. 2014/2897), arts. 1, 5(b)

Commencement

I1

Art. 17 in force at 5.12.2012, see art. 1