In the Annex to Decision 2003/43/EC, Table 1 is replaced by the following:

‘

Table 1

Classes of reaction to fire performance for wood-based panels

Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3.

A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.

Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3.

Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3.

Veneered, phenol- and melamine-faced panels are included for class excl. floorings.

A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.

Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.

Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.

ProductEN product standardEnd use conditionf1 Minimum density(kg/m3)Minimum thickness(mm)Classf2(excluding floorings)Classf3(floorings)
Cement-bonded particleboardf4 EN 634-2without an air gap behind the panel1 00010B-s1, d0Bfl-s1
Fibreboard, hard EN 622-2without an air gap behind the wood-based panel9006D-s2, d0Dfl-s1
Fibreboard, hardf5 EN 622-2with a closed air gap not more than 22 mm behind the wood-based panel9006D-s2, d2—
Particleboard,f6,f7 EN 312without an air gap behind the wood-based panel6009D-s2, d0Dfl-s1
Fibreboard, hard and medium,,

EN 622-2

EN 622-3

MDF,, EN 622-5
MDF,, EN 300
Plywood,, EN 636-“-4009D-s2, d0Dfl-s1
Solid wood panel,, EN 1335312
Flaxboard,, EN 15197-“-45015D-s2, d0Dfl-s1
Particleboard, EN 312with a closed or an open air gap not more than 22 mm behind the wood-based panel6009D-s2, d2—
Fibreboard, hard and medium,

EN 622-2

EN 622-3

MDF, EN 622-5
OSB, EN 300
Plywood, EN 636-“-4009D-s2, d2—
Solid wood panel, EN 1335312
Particleboardf8, EN 312with a closed air gap behind the wood-based panel60015D-s2, d0Dfl-s1
Fibreboard, medium, EN 622-3
MDF, EN 622-5
OSB, EN 300
Plywood, EN 636-“-40015D-s2, d1Dfl-s1
Solid wood panel, EN 13353D-s2, d0
Flaxboard, EN 15197-“-45015D-s2, d0Dfl-s1
Particleboard, EN 312with an open air gap behind the wood-based panel60018D-s2, d0Dfl-s1
Fibreboard, medium, EN 622-3
MDF, EN 622-5
OSB, EN 300
Plywood, EN 636-“-40018D-s2, d0Dfl-s1
Solid wood panel, EN 13353
Flaxboard, EN 15197-“-45018D-s2, d0Dfl-s1
Particleboard EN 312any6003EEfl
OSB EN 300
MDF EN 622-5-“-4003EEfl
2509EEfl
Plywood EN 636-“-4003EEfl
Fibreboard, hard EN 622-2-“-9003EEfl
Fibreboard, medium EN 622-3-“-4009EEfl
Fibreboard, softEN 622-4-“-2509EEfl

’

Annotations

Footnotes

f1

A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.

f2

Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.

f3

Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.

f4

Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3.

f5

Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3.

f6

A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.

f7

Veneered, phenol- and melamine-faced panels are included for class excl. floorings.

f8

Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3.