Division BAT 4 BAT is to monitor emissions to air by using the monitoring techniques with at least the minimum frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

United Kingdom

Original text. Later amendments are not shown.

Continuous measurement of SO2 emissions may be replaced by calculations based on measurements of the sulphur content of the fuel or the feed; where it can be demonstrated that this leads to an equivalent level of accuracy.

Regarding SOX, only SO2 is continuously measured, while SO3 is only periodically measured (e.g. during calibration of the SO2 monitoring system).

Refers to the total rated thermal input of all combustion units connected to the stack where emissions occur.

Or indirect monitoring of SOX.

Monitoring frequencies may be adapted if, after a period of one year, the data series clearly demonstrate a sufficient stability.

SO2 emissions measurements from SRU may be replaced by a continuous material balance or other relevant process parameter monitoring, provided appropriate measurements of SRU efficiency are based on periodic (e.g. once every 2 years) plant performance tests.

Antimony (Sb) is monitored only in catalytic cracking units when Sb injection is used in the process (e.g. for metals passivation).

With the exception of combustion units firing only gaseous fuels.

DescriptionUnitMinimum frequencyMonitoring technique

(i)

SOX, NOX, and dust emissions

Catalytic crackingContinuousf1 f2 Direct measurement

Combustion units

≥ 100 MWf3

and calcining units

Continuous Direct measurementf4

Combustion units

of 50 to 100 MW

Continuous Direct measurement or indirect monitoring

Combustion units

< 50 MW

Once a year and after significant fuel changesf5 Direct measurement or indirect monitoring
Sulphur recovery units (SRU)Continuous for SO2 onlyDirect measurement or indirect monitoringf6

(ii)

NH3 emissions

All units equipped with SCR or SNCRContinuousDirect measurement

(iii)

CO emissions

Catalytic cracking and combustion units

≥ 100 MW

ContinuousDirect measurement
Other combustion unitsOnce every 6 months Direct measurement

(iv)

Metals emissions: Nickel (Ni), Antimony (Sb)f7, Vanadium (V)

Catalytic crackingOnce every 6 months and after significant changes to the unit Direct measurement or analysis based on metals content in the catalyst fines and in the fuel
Combustion unitsf8

(v)

Polychlorinated dibenzodioxins/furans (PCDD/F) emissions

Catalytic reformerOnce a year or once a regeneration, whichever is longerDirect measurement

Annotations

Footnotes

f1

Continuous measurement of SO2 emissions may be replaced by calculations based on measurements of the sulphur content of the fuel or the feed; where it can be demonstrated that this leads to an equivalent level of accuracy.

f2

Regarding SOX, only SO2 is continuously measured, while SO3 is only periodically measured (e.g. during calibration of the SO2 monitoring system).

f3

Refers to the total rated thermal input of all combustion units connected to the stack where emissions occur.

f4

Or indirect monitoring of SOX.

f5

Monitoring frequencies may be adapted if, after a period of one year, the data series clearly demonstrate a sufficient stability.

f6

SO2 emissions measurements from SRU may be replaced by a continuous material balance or other relevant process parameter monitoring, provided appropriate measurements of SRU efficiency are based on periodic (e.g. once every 2 years) plant performance tests.

f7

Antimony (Sb) is monitored only in catalytic cracking units when Sb injection is used in the process (e.g. for metals passivation).

f8

With the exception of combustion units firing only gaseous fuels.