OpenLegislation

Division 1.3.3.1.2 Total emissions of dust and fluorides

United Kingdom

Original text. Later amendments are not shown.

BAT-associated emission levels for the total emissions of dust and fluoride to air from the electrolysis house (collected from the electrolytic cells and roof vents): See Table 12.

Table 12

BAT-associated emission levels for the total emissions of dust and fluoride to air from the electrolysis house (collected from the electrolytic cells and roof vents)

As mass of pollutant emitted during a year from the electrolysis house divided by the mass of liquid aluminium produced in the same year.

These BAT-AELs are not applicable to plants that due to their configuration cannot measure roof emissions.

ParameterBATBAT-AELs for existing plants (kg/t Al)f1 f2 BAT-AELs for new plants (kg/t Al)
DustCombination of BAT 64, BAT 65 and BAT 67≤ 1,2≤ 0,6
Total fluorides≤ 0,6≤ 0,35

The associated monitoring is in BAT 10.

The associated monitoring is in BAT 10.

  1. BAT 68Division BAT 68

Annotations

Footnotes

f1

As mass of pollutant emitted during a year from the electrolysis house divided by the mass of liquid aluminium produced in the same year.

f2

These BAT-AELs are not applicable to plants that due to their configuration cannot measure roof emissions.