OpenLegislation

Division BAT 36 In order to increase the energy efficiency of gas oil combustion in gas turbines, BAT is to use an appropriate combination of the techniques given in BAT 12 and below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability
a.Combined cycleSee description in Section 8.2

Generally applicable to new units operated ≥ 1 500 h/yr.

Applicable to existing units within the constraints associated with the steam cycle design and the space availability.

Not applicable to existing units operated < 1 500 h/yr

Table 21

BAT-associated energy efficiency levels (BAT-AEELs) for gas-oil-fired gas turbines

These BAT-AEELs do not apply to units operated < 1 500 h/yr.

Net electrical efficiency BAT-AEELs apply to CHP units whose design is oriented towards power generation, and to units generating only power.

Type of combustion unitBAT-AEELsf1
Net electrical efficiency (%)f2
New unitExisting unit
Gas-oil-fired open-cycle gas turbine> 3325–35,7
Gas-oil-fired combined cycle gas turbine> 4033–44

Annotations

Footnotes

f1

These BAT-AEELs do not apply to units operated < 1 500 h/yr.

f2

Net electrical efficiency BAT-AEELs apply to CHP units whose design is oriented towards power generation, and to units generating only power.