Division 5.1.2 Energy efficiency
United Kingdom
Table 33
BAT-associated energy efficiency levels (BAT-AEELs) for the combustion of process fuels from the chemical industry in boilers
| These BAT-AEELs do not apply to units operated < 1 500 h/yr. | ||||
| In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards generation electricity or towards heat generation). | ||||
| These BAT-AEELs may not be achievable if the potential heat demand is too low. | ||||
| These BAT-AEELs do not apply to plants generating only electricity. | ||||
| Type of combustion unit | BAT-AEELsf1 f2 | |||
|---|---|---|---|---|
| Net electrical efficiency (%) | Net total fuel utilisation (%)f3 f4 | |||
| New unit | Existing unit | New unit | Existing unit | |
| Boiler using liquid process fuels from the chemical industry, including when mixed with HFO, gas oil and/or other liquid fuels | > 36,4 | 35,6–37,4 | 80–96 | 80–96 |
| Boiler using gaseous process fuels from the chemical industry, including when mixed with natural gas and/or other gaseous fuels | 39–42,5 | 38–40 | 78–95 | 78–95 |
Annotations
Footnotes
- f1
-
These BAT-AEELs do not apply to units operated < 1 500 h/yr.
- f2
-
In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards generation electricity or towards heat generation).
- f3
-
These BAT-AEELs may not be achievable if the potential heat demand is too low.
- f4
-
These BAT-AEELs do not apply to plants generating only electricity.