Division BAT 89: In order to reduce the waste water volume and the organic load discharged to waste water treatment, BAT is to use both of the techniques given below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| a. | Optimised liquid phase separation | Separation of organic and aqueous phases with appropriate design and operation (e.g. sufficient residence time, phase boundary detection and control) to prevent any entrainment of undissolved organic material | Generally applicable |