Division BAT 90: In order to prevent or reduce emissions to water of poorly bioeliminable organic compounds, BAT is to use one of the techniques given below.
United Kingdom
| Technique | Description | |
|---|---|---|
| a. | Adsorption | See Section 12.2. Adsorption is carried out prior to sending waste water streams to the final biological treatment |
| b. | Waste water incineration | See Section 12.2 |
Applicability:
Only applicable to waste water streams carrying the main organic load from the hydrogen peroxide plant and when the reduction of the TOC load from the hydrogen peroxide plant by means of biological treatment is lower than 90 %.