Division SCOPE
United Kingdom
These BAT conclusions concern the following activities specified in Annex I to Directive 2010/75/EU:
- 5.2.
Disposal or recovery of waste in waste incineration plants:
- (a)
for non-hazardous waste with a capacity exceeding 3 tonnes per hour;
- (b)
for hazardous waste with a capacity exceeding 10 tonnes per day.
- (a)
- 5.2.
Disposal or recovery of waste in waste co-incineration plants:
- (a)
for non-hazardous waste with a capacity exceeding 3 tonnes per hour;
- (b)
for hazardous waste with a capacity exceeding 10 tonnes per day;
whose main purpose is not the production of material products and where at least one of the following conditions is fulfilled:
-
only waste, other than waste defined in Article 3(31)(b) of Directive 2010/75/EU, is combusted;
-
more than 40 % of the resulting heat release comes from hazardous waste;
-
mixed municipal waste is combusted.
- (a)
- 5.3.
- (a)
Disposal of non-hazardous waste with a capacity exceeding 50 tonnes per day involving the treatment of slags and/or bottom ashes from the incineration of waste.
- (a)
- 5.3.
- (b)
Recovery, or a mix of recovery and disposal, of non-hazardous waste with a capacity exceeding 75 tonnes per day involving the treatment of slags and/or bottom ashes from the incineration of waste.
- (b)
- 5.1.
Disposal or recovery of hazardous waste with a capacity exceeding 10 tonnes per day involving the treatment of slags and/or bottom ashes from the incineration of waste.
These BAT conclusions do not address the following:
-
Pre-treatment of waste prior to incineration. This may be covered by the BAT conclusions for Waste Treatment (WT).
-
Treatment of incineration fly ashes and other residues resulting from flue-gas cleaning (FGC). This may be covered by the BAT conclusions for Waste Treatment (WT).
-
Incineration or co-incineration of exclusively gaseous waste, other than that resulting from the thermal treatment of waste.
-
Treatment of waste in plants covered by Article 42(2) of Directive 2010/75/EU.
Other BAT conclusions and reference documents which could be relevant for the activities covered by these BAT conclusions are the following:
-
Waste Treatment (WT);
-
Economics and Cross-Media Effects (ECM);
-
Emissions from Storage (EFS);
-
Energy Efficiency (ENE);
-
Industrial Cooling Systems (ICS);
-
Monitoring of Emissions to Air and Water from IED Installations (ROM);
-
Large Combustion Plants (LCP);
-
Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW).