OpenLegislation

Division BAT 18 In order to reduce dust emissions in waste gases from substrate surface preparation, cutting, coating application and finishing processes for the sectors and processes listed in Table 2, BAT is to use one or a combination of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescription
(a)Wet separation spray booth (flushed impact panel)A water curtain cascading vertically down the spray cabin rear panel captures paint particles from overspray. The water-paint mixture is captured in a reservoir and the water is recirculated.
(b)Wet scrubbingPaint particles and other dust in the off-gas are separated in scrubber systems by intensive mixing of the off-gas with water. (For VOC removal, see BAT 15 (c).)
(c)Dry overspray separation with pre-coated materialA dry paint overspray separation process using membrane filters combined with limestone as pre-coating material to prevent fouling of the membranes.
(d)Dry overspray separation using filtersMechanical separation system, e.g. using cardboard, fabric or sinter.
(e)Electrostatic precipitatorIn electrostatic precipitators, particles are charged and separated under the influence of an electrical field. In a dry electrostatic precipitator (ESP), the collected material is mechanically removed (e.g. by shaking, vibration, compressed air). In a wet ESP, it is flushed with a suitable liquid, usually a water-based separation agent.

Table 2

BAT-associated emission levels (BAT-AELs) for dust emissions in waste gases

ParameterSectorProcessUnitBAT-AEL(Daily average or average over the sampling period)
DustCoating of vehiclesSpray coatingmg/Nm3 < 1–3
Coating of other metal and plastic surfacesSpray coating
Coating of aircraftPreparation (e.g. sanding, blasting), coating
Coating and printing of metal packagingSpray application
Coating of wooden surfacesPreparation, coating

The associated monitoring is given in BAT 11.