Division BAT 11 BAT is to monitor emissions in waste gases with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
United Kingdom
| To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions. | |||||
| In the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality. | |||||
| For the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window. | |||||
| Generic EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181. | |||||
| The monitoring only applies if DMF is used in the processes. | |||||
| In the absence of an EN standard, the measurement includes the DMF contained in the condensed phase. | |||||
| In the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years. | |||||
| Substance/Parameter | Sectors/Sources | Standard(s) | Minimum monitoring frequency | Monitoring associated with | |
|---|---|---|---|---|---|
| Dust | Coating of vehicles – Spray coating | EN 13284-1 | Once every yearf1 | BAT 18 | |
| Coating of other metal and plastic surfaces – Spray coating | |||||
| Coating of aircraft – Preparation (e.g. sanding, blasting) and coating | |||||
| Coating and printing of metal packaging – Spray application | |||||
| Coating of wooden surfaces – Preparation and coating | |||||
| TVOC | All sectors | Any stack with a TVOC load < 10 kg C/h | EN 12619 | Once every year f2 f3 | BAT 14, BAT 15 |
| Any stack with a TVOC load ≥ 10 kg C/h | Generic EN standardsf4 | Continuous | |||
| DMF | Coating of textiles, foils and paperf5 | No EN standard availablef6 | Once every three months | BAT 15 | |
| NOX | Thermal treatment of off-gases | EN 14792 | Once every yearf7 | BAT 17 | |
| CO | Thermal treatment of off-gases | EN 15058 | Once every year | BAT 17 | |
Annotations
Footnotes
- f1
-
To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.
- f2
-
In the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality.
- f3
-
For the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window.
- f4
-
Generic EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181.
- f5
-
The monitoring only applies if DMF is used in the processes.
- f6
-
In the absence of an EN standard, the measurement includes the DMF contained in the condensed phase.
- f7
-
In the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years.