OpenLegislation

Division BAT 11 BAT is to monitor emissions in waste gases with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

United Kingdom

Original text. Later amendments are not shown.

To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.

In the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality.

For the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window.

Generic EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181.

The monitoring only applies if DMF is used in the processes.

In the absence of an EN standard, the measurement includes the DMF contained in the condensed phase.

In the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years.

Substance/ParameterSectors/SourcesStandard(s)Minimum monitoring frequencyMonitoring associated with
DustCoating of vehicles – Spray coatingEN 13284-1Once every yearf1 BAT 18
Coating of other metal and plastic surfaces – Spray coating
Coating of aircraft – Preparation (e.g. sanding, blasting) and coating
Coating and printing of metal packaging – Spray application
Coating of wooden surfaces – Preparation and coating
TVOCAll sectorsAny stack with a TVOC load < 10 kg C/hEN 12619Once every year f2 f3 BAT 14, BAT 15
Any stack with a TVOC load ≥ 10 kg C/hGeneric EN standardsf4 Continuous
DMFCoating of textiles, foils and paperf5 No EN standard availablef6 Once every three months BAT 15
NOX Thermal treatment of off-gasesEN 14792Once every yearf7 BAT 17
COThermal treatment of off-gasesEN 15058Once every year BAT 17

Annotations

Footnotes

f1

To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.

f2

In the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality.

f3

For the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window.

f4

Generic EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181.

f5

The monitoring only applies if DMF is used in the processes.

f6

In the absence of an EN standard, the measurement includes the DMF contained in the condensed phase.

f7

In the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years.