Division BAT 12 BAT is to monitor emissions to water with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
United Kingdom
| The monitoring only applies in the case of direct discharge to a receiving water body. | ||||
| The monitoring frequency may be reduced to once every 3 months if the emission levels are proven to be sufficiently stable. | ||||
| In the case of batch discharge that is less frequent than the minimum monitoring frequency, monitoring is carried out once per batch. | ||||
| TOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds. | ||||
| Monitoring of Cr(VI) only applies if chromium(VI) compounds are used in the processes. | ||||
| In the case of indirect discharge to a receiving water body, the monitoring frequency may be reduced if the downstream waste water treatment plant is designed and equipped appropriately to abate the pollutants concerned. | ||||
| Monitoring of Cr only applies if chromium compounds are used in the processes. | ||||
| Monitoring of F- only applies if fluorine compounds are used in the processes. | ||||
| Substance/Parameter | Sector | Standard(s) | Minimum monitoring frequency | Monitoring associated with |
|---|---|---|---|---|
| TSSf1 | Coating of vehicles | EN 872 | Once every monthf2 f3 | BAT 21 |
| Coil coating | ||||
| Coating and printing of metal packaging (only for DWI cans) | ||||
| COD f4 | Coating of vehicles | No EN standard available | ||
| Coil coating | ||||
| Coating and printing of metal packaging (only for DWI cans) | ||||
| TOC | Coating of vehicles | EN 1484 | ||
| Coil coating | ||||
| Coating and printing of metal packaging (only for DWI cans) | ||||
| Cr(VI)f5 f6 | Coating of aircraft | EN ISO 10304-3 or EN ISO 23913 | ||
| Coil coating | ||||
| Cr f7 | Coating of aircraft | Various EN standards available (e.g. EN ISO 11885, EN ISO 17294-2, EN ISO 15586) | ||
| Coil coating | ||||
| Ni | Coating of vehicles | |||
| Coil coating | ||||
| Zn | Coating of vehicles | |||
| Coil coating | ||||
| AOX | Coating of vehicles | EN ISO 9562 | ||
| Coil coating | ||||
| Coating and printing of metal packaging (only for DWI cans) | ||||
| F- f8 | Coating of vehicles | EN ISO 10304-1 | ||
| Coil coating | ||||
| Coating and printing of metal packaging (only for DWI cans) | ||||
Annotations
Footnotes
- f1
-
The monitoring only applies in the case of direct discharge to a receiving water body.
- f2
-
The monitoring frequency may be reduced to once every 3 months if the emission levels are proven to be sufficiently stable.
- f3
-
In the case of batch discharge that is less frequent than the minimum monitoring frequency, monitoring is carried out once per batch.
- f4
-
TOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds.
- f5
-
Monitoring of Cr(VI) only applies if chromium(VI) compounds are used in the processes.
- f6
-
In the case of indirect discharge to a receiving water body, the monitoring frequency may be reduced if the downstream waste water treatment plant is designed and equipped appropriately to abate the pollutants concerned.
- f7
-
Monitoring of Cr only applies if chromium compounds are used in the processes.
- f8
-
Monitoring of F- only applies if fluorine compounds are used in the processes.