OpenLegislation

Division 2.2.2.1 F1F2F3

United Kingdom

Original text. Later amendments are not shown.

Standardisation of the test procedure for individual serum samples:

  1. (a)

    a 1/150 pre-dilution f1 of the OIEISS or a 1/2 pre-dilution of the OIEELISA WP SS or a 1/16 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) must give a positive reaction;

  2. (b)

    a 1/600 pre-dilution of the OIEISS or a 1/8 pre-dilution of the OIEELISA WP SS or a 1/64 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) must give a negative reaction;

  3. (c)

    the OIEELISA N SS must always give a negative reaction.

Annotations

Textual amendments

F1

Substituted by Council Directive 97/12/EC of 17 March 1997 amending and updating Directive 64/432/EEC on health problems affecting intra-Community trade in bovine animals and swine.

F2

Substituted by Commission Regulation (EC) No 535/2002 of 21 March 2002 amending Annex C to Council Directive 64/432/EEC and amending Decision 2000/330/EC.

F3

Substituted by Commission Decision of 10 December 2008 amending Annex C to Council Directive 64/432/EEC and Decision 2004/226/EC as regards diagnostic tests for bovine brucellosis (notified under document number C(2008) 7642) (Text with EEA relevance) (2008/984/EC).

Footnotes

f1

For the purpose of this Annex, dilutions given for making up liquid reagents are expressed as, for example, 1/150 shall mean a 1 in 150 dilution.